Hytera PT890Ex Intrinsically Safe TETRA Radio – Reliable

About The Hytera PT890Ex Intrinsically Safe TETRA Radio – Reliable

The Hytera PT890Ex is a robust, intrinsically safe TETRA radio built for hazardous environments. Certified to stringent IECEx/ATEX standards, it ensures reliable communication in industries like oil and gas, firefighting, and manufacturing. Its 2W speaker with AI noise reduction delivers crystal-clear audio even in noisy settings, while Class 3L transmission power ensures extended coverage in remote areas.

Designed for safety, the PT890Ex features a high-grade battery with anti-spark protection, a novel locking system, and anti-counterfeit identification. Its durable build and explosion-proof materials allow operation in extreme temperatures from –25°C to 60°C.

The PT890Ex also enhances safety with man-down alarms and precise location tracking. Advanced connectivity options, including BT 5.3, WLAN, and NFC, support versatile applications. With a user-friendly interface, large screen, and multifunctional buttons, the PT890Ex is the ultimate solution for safe, efficient communication in demanding environments.

Important Note to Customers:
The Hytera PT890Ex is a specialist radio designed for specific hazardous applications. Please contact us at 1300 266 682 before purchasing to confirm it meets your needs.

Contact Us For A Quote

Get A Quote

Hytera PT890Ex Intrinsically Safe TETRA Portable Radio

  • Certified Safety:Meets IECEx/ATEX standards for explosion-proof environments, ensuring safe operation in industries like oil and gas, firefighting, and manufacturing.

 

  • Clear Audio: 2W speaker with AI noise reduction and automatic gain control provides loud, clear communication, even in noisy surroundings.

 

  • Extended Coverage: Class 3L transmission power reduces blind spots and ensures reliable communication in remote areas.

 

  • Reliable Battery: Features a high-grade battery with spark-proof locking, anti-counterfeiting identification, and intelligent power-saving for extended operation.

 

  • Temperature Resilience: Operates in extreme conditions from –25°C to 60°C with enhanced heat dissipation for reliability.

 

  • Enhanced Safety Features: Includes man-down alarms and location tracking for quick response in emergencies.
  • Advanced Connectivity: Supports Bluetooth 5.3, WLAN, and NFC for versatile third-party applications and remote management.
  • User-Friendly Design: Upgraded 2.4-inch screen, intuitive UI, multifunctional buttons, and large LED indicators for efficient operation.
  • Durable Construction: Explosion-proof materials and rugged design make it suitable for challenging environments.
  • Versatile Applications: Ideal for industries requiring reliable communication and robust safety measures.

Additional information

View our CONNECTOR CHART to find your connector

K

Kenwood Two Pin Right Angle

3.5mm Stereo + 2.5mm Mono

Kenwood:
TK-250/350, 260/360, 260G/360G, 270/370, 270G/370G, TK-3100(ProTalk), TK-3103(Free Talk XL), TK-3102(Pro Power), TK-2160/3160, TK-2170/3170, TL-3130(ProTalk XLS), 3131(Free Talk XLS), TK-2207/3307, TK-2317/3317, TK-3310, TK-2360/3360, NX220/320, NX240/340

Hytera:
HYT TC-368

K2

Kenwood Multiple Pin

Kenwood:
TK-280, TK-290, TK-380, TK-385, TK-390, TK-480, TK-481, TK-2041, TK-2140, TK-3140, TK-3148, TK-2180, TK-3180, NX-200, NX300

K4

Kenwood Single Pin

Kenwood:
PKT-23

M

Motorola Two Pin Right Angle

3.5mm Mono + 2.5mm Mono

Motorola:
GP68, GP88, GP300, GP308, GP350, P040, P110, P1225, P1225LS, P2000, CP88, CP125, CP150, CP200, CT150, CT250, CT450, CT450LS, CP476, PRO2150, PRO3150, BRP40, EP450, MTH500, GTX, SP50, LTS2000, PR400

M4

Motorola Multiple Pin

Motorola:
HT750, HT1250, HT1250LS, HT1550, HT1550XLS, MTX850, MTX850LS, MTX900, MTX950, MTX960, MTX8250, MTX8250LS, MTX9250, PRO5150, PRO5350, PRO5450, PRO5550, PRO5750, PRO7150, PRO7350, PRO7450, PRO7550, PRO7750, PRO9150, PTX780, GP140, GP320, GP328, GP329, GP330, GP338, GP339, GP340, GP360, GP380, GP600, GP640, GP650, GP680, GP1280

M5

Motorola Multiple Pin

Hytera Multiple Pin

Simoco Multiple Pin

Motorola:
EX500, EX600, GL2000, GP328Plus, GP338Plus, GP628 Plus, PTX760Plus, GP344, GP388, PRO5150Elite

Hytera:
TC380M, TC370M, TC780M, TC780

Simoco:
SRP9170, SRP9180, SDP650, SDP660

M6

Motorola Multiple Pin

Motorola:
GP900, GP9000, HT1000, JT1000, MT2000, MTS2000, MT6000, MTX838, MTX900, MTX1000, MTX8000, MTX9000, MTXLS, XTS2000, XTS2500, XTS3000, XTS3500, XTS5000, XTS5100, XTS7700

M7

Motorola Multiple Pin

Motorola:
MOTOTRBO, APX6000, APX7000, XPR6300, XPR6500, XPR6350, XPR6550, DP3400, DP3600, DP3401, DP3601, DP4400, DP4600, DP4401, DP4601

M10

Motorola Single Pin

Motorola:
CLP107, CLP117

M12

Motorola Multiple Pin

Motorola:
DP2000, DP2400, DP2600, DP3440, DP3441, XPR3300, XPR3500

MT1B

Motorola Single Pin

Motorola:
MTP850, MTH500, MTH650, MTH800

Y2

Vertex Single Pin Right Angle

3.5mm With Screws

Vertex:
VX-160, VX-180, VX-210, VX-210A, VX-231, VX-351, VX-410, VX-420, VX-426, VX-451, VX-454, VX-459, EVX-531

Y6

Vertex Multiple Pin Right Angle

Vertex:
VX-820, VX-821, VX-824, VX-829, VX-920, VX-921, VX-929, VXD-720

D1

Delta Two Pin Right Angle

Delta:
Pro16, 16L, 200B, 200K

D3

Delta Two Pin Right Angle

3.5mm Stereo + 2.5mm Mono

Delta:
AS300, AS310, AS320

D7

Delta Multiple Pin Right Angle

Delta:
DS400, DS410, DS420

S1

Icom, GME, Vertex Two Pin Straight

3.5mm Mono + 2.5mm Mono

Icom:
IC-F3, IC-F3S, IC-F4, IC-F10, IC-40S, IC-F20, IC-H2, IC-H6, IC-J12, IC-M5, IC-U12, IC-U16, IC-36FI

GME:
TX610, TX6000, TX7000, TX655

Vertex:
VX-200, VX-500, VX-510, VX-520UD

Cobra, Ritron

S2

Icom Two Pin Right Angle

3.5mm Mono + 2.5mm Stereo

Icom:
IC-F3G, IC-F3GS, IX-G3GT, IC-F4G, IC-F4GS, IC-F4GT, IC-F43GS, IC-F43GT, IC-F43TR, IC-F11, IC-F11S, IC-F21, IC-F21S, IC-F31, IC-A24

S3

Icom Two Pin Right Angle

3.5mm Mono + 2.5mm Stereo

Icom:
IC-F3G, IC-F3GS, IC-F4G, IC-F4GS, IC-F11, IC-F21, IC-F31, IC-F33, IC-F43, IC-F14, IC-F24, IC-F3023, IC-F4023, IC-41S, IC-41W, IC-41Pro, IC-F3003, IC-F4003, IC-F3130D, IC-4140D

S4

Icom Multiple Pin Right Angle

Icom:
IC-F50, IC-F51, IC-F60, IC-F61, IC-F30G, IC-F30GT, IC-F30GS, IC-F31GS, IC-F31GT, IC-36FI, IC-F40G, IC-F40GS, IC-F40GT, IC-35FIM87/88, IC-F3163, IC-F4163, IC-F3163D, IC-F4163D

SC1

Simoco Two Pin Right Angle

5mm Stereo + 2.5mm Stereo

Simoco:
SRP9120 SRP9130

H1

Hytera Two Pin Right Angle

3.5mm Mono + 2.5mm Mono

Hytera:
HYTS2100, TC500, TC600, TC2100, TC446, TC700, TC610, TC620

H2

Hytera Multiple Pin Right Angle

Hytera:
PD702, PD782, PD780, PT580, PD780G

H3

Hytera Two Pin Right Angle

Hytera:
TC700, TC610, TC620, PD500 Series

H5

Hytera Multiple Pin Right Angle

Hytera:
PD600 Series, X1E, X1P, TC380M, TC370M, TC780M, TC780, TC3000, TC610P

ATEX, UL & IECEx Guide

Please note that Radio Industries Australia Pty Ltd does not classify or take responsibility for the Hazardous Location Settings mentioned in this page, this is just a guide. Please consult your Safety Department for your exact Hazardous Location requirements.

What is Intrinsically Safe?

Intrinsically safe is a term used to describe a collection of devices and equipment that meet the requirements set out by the certification body (ATEX, UL or IECEx) to determine that device or equipment’s safety when used in a hazardous environment.

What is a Hazardous Environment?

A Hazardous Environment is an area where fumes, dust, gas or vapour may cause a fire or explosion when an ignition source is used in the area. For example, you may see a ‘No Naked Flames’ sign in your petrol station when filling up your car, this is because the area is classed as a Hazardous Environment. People who use devices like Two-Way Radios in these environments need to ensure that the device itself complies with the standard set for that particular zone. Often a safety officer will have this information to hand and be able to direct you as to what type of equipment you need for different areas of your plant.

What is the difference between ATEX, UL and IECEx?

The difference between these three is the testing/classification body.

Each rating is created by a recognised standards body with ATEX Being European, UL being American and IECEx often used for international standards. Your company may choose a specific standard to base decisions from.

ATEX Explained

Download the CML ATEX/IECEx Guide HERE - https://www.cmlex.com/wp-content/uploads/hazardous-area-guide.pdf

An ATEX Label will tell you exactly where the equipment can be used based on the Equipment classification and Zones specified. All of the numbers and letters on the label correspond to the level of protection offered and in what environments the equipment can be used. Please consult your safety supervisor for the correct equipment class you require based on the zones you are subject to.

ATEX Equipment is classified by Group, Type of protection, Gas/Dust Group, Temperature class and equipment protection level.

Areas where ATEX must be used is classified by Zones. Each Zone is for a particular Hazardous Environment. Each Zone is explained below. You will then need to use equipment suitable and certified for use the Zone.

ATEX Zones

Combustible Gas & Vapour

Gas Zone Description ATEX Category EPL Required Protection
Methane Mines with methane and dust. Equipment remains energised in explosive atmosphere. M1 Ma Two Faults
Methane Mines with methane and dust. Equipment is de-energised in explosive atmosphere. M2 Mb Severe Normal Operation
Zone 0 A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is present continuously or for long periods or frequently. 1G Ga Two Faults
Zone 1 A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. 2G Gb One Fault
Zone 2 A place in which an explosive atmosphere consisting of a mixture with air of dangerous substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. 3G Gc Normal Operation

Combustible Dust & Fibres

Dust Zone Description ATEX Category EPL Required Protection
Zone 20 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently. 1D Da Two Faults
Zone 21 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. 2D Db One Fault
Zone 22 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. 3D Dc Normal Operation

Equipment Groups

Equipment Group Description
Group I

Electrical equipment intender for use in mines susceptible to fire damp

Group II A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally.
Group III Electrical equipment intended for use in explosive dust atmospheres

IECEx Explained

IECEx is very similar to ATEX however some of the definitions for the protection offered do differ so keep that in mind.

Download the CML ATEX/IECEx Guide HERE - https://www.cmlex.com/wp-content/uploads/hazardous-area-guide.pdf

UL Explained

UL is classified by Divisions and Classes. The classes define the substance whilst the Division defines the operating conditions. The classes are also split into subgroups to determine specific and/or equivalent substances.

Classes
  • Class I – Flammable Gases, Vapours or Liquids

    • Group A - Acetylene and equivalent gas groups​

    • Group B - Hydrogen and equivalent gas groups ​

    • Group C - Ethylene and equivalent gas groups ​

    • Group D - Methane, and equivalent gas groups 

  • Class II – Combustible Dust

    • Group E - Conductive dust (mechanical – factories, recyclers)

    • Group F - Combustible carbon dust (charcoal & coke dust) - above ground only​

    • Group G - Grain dust

  • Class III – Ignitable Fibres and Flyings (No Subgroups)
Divisions

Division 1 - Locations where ignitable gas/vapor/liquid/dust are present continuously or some of the time under normal operating conditions. 

Division 2 - Locations where ignitable gas/vapor/liquid/dust are not likely to exist under normal operating conditions.

Based on the above a rating of ‘Class I, Div 1, Group C, D’ would be given to an environment where Ethylene and Methane are expected to be present continuously

Why Choose Us?

Radio Industries is one of Australia’s longest-running Two Way Radio Communications Companies, operating since 1985. We are Dealers and Distributors of Quality Digital & Analogue Two-Way Radio Systems, and Hearing Protection Equipment.

What Our Customers Think

“Good experience. Product arrived in 2 days, sent express and completely as advertised. Called at one stage about shipping and they were easy to deal with. Happy with the product quality. Would recommend as easy to speak to someone if you have any questions. Great that they request your radio type too to make sure you’re buying the right connection. Thanks guys!”
John Johnson

“Thank you for your assistance with this matter, the whole process from the ‘chat’ onward through invoicing and payment, has been simple and fast. A pleasure to deal with you and your company. Well done from a business perspective, even for an out of the blue approach regarding a relatively minor order.
Regards, and again, thank you for your help.”

Michael Hayes

“Jim and Jacob sorted our order efficiently and quickly. We had our radios here and ready to use 5 days after payment was made. Very impressed with the professionalism of both employees and they really helped us out because we were looking for units that were in high demand and low in stock.”
Tarah Ferguson

Frequently Asked Questions

How Far Can I Get?

Two-Way Radios work on line of sight.

What Channels Can I Use?

CB or Private frequency.

Which Radio Is Best?

There is no definitive answer as there are too many radios to choose from, they work on different systems, contact us for a quote.

Do I Need A Private Frequency?

If you are using your radios on a crane then a private frequency is required in order to comply with OH&S.

If you will be using radios for safety reasons then a private frequency is recommended in order to prevent unnecessary outside interference that can easily be caused with standard UHF CB radios.

What is the difference between a Two-Way Radio, Walkie Talkie and Handy Talkie

Nothing, they all refer to the same piece of equipment however a Two-Way Radio is the preferred terminology in industry. Walkie Talkies and Handy Talkies often refer to toys or recreational two-way radios.

Customers Also Bought…

Cart

Product categories